catalogue ******************************************************************************** low cost power supply for general purpose application lcs series single output power supply: 35 / 50 / 100 / 150 watt. ac ? dc enclosed. features ? input voltage range 115 / 230 vac ? certified to ice 60950 ? emi: conform to en55022-a ? ems: conform to en61000-4-2,4,5,11 ? screw terminal for input / output connections. lcs series industrial power supply specifications model voltage max output current (a) rippie & noise (mv p-p) effciency lcs35-5 5v 7.0 75 73 lcs35-12 12v 3.0 100 75 lcs35-24 24v 1.5 100 80 lcs50-5 5v 10.0 75 74 lcs50-12 12v 4.2 100 77 lcs50-24 24v 2.1 100 81 lcs100-5 5v 20.0 100 75 lcs100-12 12v 8.5 100 79 lcs100-24 24v 4.5 100 83 lcs150-5 5v 30.0 150 77 lcs150-12 12v 12.5 180 80 lcs150-24 24v 6.5 240 84
lcs series industrial power supply specifications input lcs50-100 ac: 85~132vac / 170~264vac (user selectable) input voltage range lcs150 ac: 88~132vac / 176~264vac (user selectable) input voltage frequency 47-63 hz lcs35 0.8a @ 115vac & 0.45a @ 230vac lcs50 1.3a @ 115vac & 0.65a @ 230vac lcs100 2.4a @ 115vac & 1.2a @ 230vac input current lcs150 3.2a @ 115vac & 1.6a @ 230vac lcs35 & 50 18a @ 115vac & 36a @ 230vac inrush current, at cold start lcs100 & 150 20a @ 115vac & 40a @ 230vac output lcs35 & 50 0.5% of nominal rated output voltage line regulation lcs100 & 150 0.5% for 5v, 0.3 for 12v, 0.2% for 24v lcs35 & 50 1.0% for 5v, 0.5% for 12v & 24v load regulation lcs100 & 150 0.5% for 5v, 0.3 for 12v, 0.2% for 24v adjustment range (v) 10% temperature drift <0.03%/ 0 c (-10 0 c~50 0 c) rise time 300msec max, 100% output loading @ 230vac lcs35 30msec min, 100% output loading @ 230vac hold up time lcs50~150 20msec min, 100% output loading @ 230vac lcs35 & 50 zener clamping at vo>110%, non auto recovery over voltage protection (ovp) lcs100 & 150 125%120%@i/p:115/230vac, auto recovery over current protection (ovp) lcs100 & 150 105% 30secs over voltage protection (ovp) lcs100 & 150 power supply will shutdown, reset by recycle ac on/off environmental emc standard conforms to en55022 class a (conducted and radiated), iec61000-4-2,4,5,11 lcs35 & 50 -10 0 c@80%, 0~50 0 c@100%,60 0 c@60% load convection cooled 5v: -10 0 c@80%,0~35 0 c@100%,60 0 c@50% load 12v & 24v: -10 0 c@80%, 0~50 0 c@100%, 60 0 c@60% load force air cooled lcs100 -10 0 c@80%,0~50 0 c@100%,60 0 c@60% load convection cooled 5v % 12v: -10 0 c@80%,0~30 0 c@100%,60 0 c@40% load 24v: -10 0 c@80%, 0~50 0 c@100%, 60 0 c@60% load force air cooled operating temperature lcs150 -10 0 c@80%,0~50 0 c@100%,60 0 c@60% load operating humidity 20%~90% rh storage temperature -20~85 0 c storage humidity 10%~95% rh vibration 10~55hz, 2g 1min/1 cycle for 60min period on each axis safe approval certified to iec60950 (cb certification) general withstand voltage input to output: 3kvac, input to fg: 2.5kvac, output to fg: 0.5kvac, 1 minute isolation resistance input to output, input to fg, input to fg: 500vdc/100mohms leakage current <3.5ma/240vac lcs35 129 x 98 x 38 lcs50 160 x 98 x 38 lcs100 199 x 98 x 38 physical dimension l x w x h (mm) lcs150 200 x 110 x 50 note : 1. all parameters are specified at 115 & 230vac input, rated load, 25 0 c ambient, 70% rh 2. tolerance - include set up toleranc e, line regulation, load regulation 3. ripple & noise measured 305mm (12") away from smps on cable connecting smps to load. measurement point has 0.1 f & 47 f capacitor connect ed across cables, oscilloscope bandwidth 20 mhz & cables should be twisted 4. line regulation is measured from low line to high line at rated load 5. load regulation is measured from 0% to 100%, at 115 & 230vac 6. warranty conditional for operating up to 100% load, at 115 & 230vac, ta=30 0 c average at recommended mounting ( refer to derating curve) 7. emi guaranteed at 100-120vac/200-240va at rated load.
low cost power supply for general purpose application warranty 1 year derating lcs35 & lcs50 lcs100 & lcs150 lcs100 lcs150 nha? phaan phoi chnh th?c ta?i vie?t nam authorised distributor in vietnam: mounting a mounting b mounting c load 100 % -10 0 50 ta( 0 c) mounting a forced air -1 0 0 50 ta ( 0 c ) 12v&24v; 5v (forced air cooled) 5v load 100 % 24v; 5v&12v (forced air cooled) 5v&12v load 100 % -1 0 0 50 ta ( 0 c ) mounting b forced air forced air cooling: 0.57m3/min direct at cavities of cover forced air mounting c
|